Sauna controller
Sauna controller MVS2
Basic operational parameters:
- automatic control of switching on and switching off of the furnace heating
- automatic control of lighting in the sauna
- automatic control of ventilation in the sauna
- automatic reading of the temperature
- automatic switching on of the sauna after the fixed time expires
- automatic switching off of the sauna after the fixed time expires
- manual switching on or switching off of the lighting, the fan
- manual switching off of the controller
- setting the own parameters of sauna heating
- output to the sauna lighting lamp
- output to the sauna fan
- control output for the furnace contactor
| Electrical parameters |
|
| Power supply | 230V/50Hz |
| Maximum total power consumption | 200W |
|
Maximum power consumption by the relay of the contactor |
30W |
|
The maximum power consumption of the lighting circuit |
150W |
|
The maximum power consumption of the fan circuit |
50W |
| Power consumption of the control system | 4W |
| Fuses |
|
| Glass fuse type F (fast) | 1A/250V |
| Short-circuit limit current | 40A |
| Dimensions | 5x20 mm |
| Operating conditions |
|
| Operating temperature | 0ºC~+40ºC |
| Relative humidity (without condensation) | 10%~80% |
| Maximum operating height of height above sea level | 1000m n.p.m. |
| The storage conditions |
|
| Storage temperature | -25ºC~+55ºC |
| Short-term storage temperature (up to 24 hours) | +70ºC |
| Relative humidity (without condensation) | 10%~80% |
| Dimensions (length x width x depth) |
|
| Control panel | 120x69,5x26,5 |
| executive module | 138x89,65x62,7 |
| temperature sensor | 36x33,3x21 |